Model NO.:TBS-A, B49H, B49X
Warranty:1 Year
Certification:CE, UL, RoHS
Material:SS304
Process Temperature:-190~425℃
Pressure:16MPa
Ex-Proof:Anti-Explosion
Connection:Flange, Thread
Warranty Period:1year
Transportation:Shipping, Air Freight
Export Markets:Global
Trademark:U-ideal
Transport Package:Wooden Case or Carton
Specification:SGS
Origin:Tianjin, China
HS Code:90261000
TBS-S Sight glass level gauge
TBS-S Sight glass level gauges are made according to the standard of the former chemical ministry HG5-1364~1370-80. This type level gauge can be used to show directly the liquid level of tower, tank, groove, and cases.
Characteristics
Directly reading, can assure the reading accuracy and reliable.
Simple structure and convenient maintenance.
Safety in use and long time in service.
Working principle
Lead fluid in tank to outer to sight glass level gauge based on the communicator theory. And they show the actual liquid level directly through the transparent glass.
Sight Glass type Level Gauges select flexible graphite plunger ring as gasket to assure seal ability.
Main technique parameters
Measure ranges (installing center to center L): 300mm, 500mm, 800mm, 1100mm, 1400mm, 1700mm (For other sizes we can make according to customer's requirements).
Working pressures: 2.5MPa, 4.0MPa, 6.3MPa, 0.6MPa and other selectable.
Material: Carbon steel, Stainless steel and others.
Working temperature: -20~+200º C
Tank opening dimension: 71mm*931mm or 68mm*928mm
Welding size: 70mm*930mm
Glass Level Gauge
Flat /Armored Glass Level Indicator
Sight glass tubular level gauge
Flowmeterlevel indicatorpressure transmitterSight Glass
Pressure reducing & sustaining valve, gate valve, check valve,
Ball valve, steam traps, strainers
Related products: Level Meter / boiler level gauge / liquid level transmitter / stainless steel valves
Serious Glass Sheet Level Gauge is a kind of sight glass level gauge which can show the liquid level directly. These type level gauges are widely used in chemical industries and petroleum field.
Glass type: borosilicate glass/mico/quartz
Gasket material: graphite gasket
Pressure for steel ball shut off automatically: ≥0.2Mpa
Steam pressure: ≤0.6Mpa. Steam sheath joint: G1/2″male thread
Measure range: 300~3000mm
Working temperature:-20~450ºC
Working pressure: 0.6MPa, 2.5Mpa, 4.0MPa, 6.3MPa, 16MPa
Meter material: carbon steel, SS304 or SS316.
Transmit color: nature color, or bi-color type(green for liquid, red for air)
Ordinary globe valve or 1/4 opens or close valve.
Lamp lighting: fluorescent lamp power supply AC36V
Glass sizes: 140mm, 165mm, 190mm, 218mm, 260mm, 280mm, 290mm, 320mm, 340mm;
Connection center to center distance 10mm adjustable.
When open the packing, firstly check the substance, and tight the bolt again. And then according to the picture equip with the accessories.
1) C-C distance: 350~2600mm
2) Working temperature: ≤450ºC
3) Working pressure: ≤16MPa
4) Meter material: carbon steel or 1Cr18Ni9Ti
5) Transmit color: nature color
1) Measure ranges: 300~2000mm
2) Work temperature: 0~450ºC
3) Working pressure: ≤16MPa
4) Needle switch close automatically pressure: ≥0.2MPa
5) steam insulating sheath pressure: ≤0.6MPa
6) flange material: qualitative carbon steel or 1Cr18Ni9Ti
Color: natural color
Name: flat sight glass level indicator
Nominal pressure: 2.5~4.0MPa
Nominal diameter: 25mm
Nominal length: 350mm, 440mm
Medium temperature: <250 C degree
Material: Q235-A quality carbon steel
Color: natural color
Name: flat sight glass level indicator
Nominal pressure: 1.6~4.0MPa
Nominal diameter: 25mm
Nominal length: 300~440mm
Medium temperature: <250 C degree
Material: Q235-A quality carbon steel or SS304
Color: bi-color ( red for air, green for liquid)
Nominal pressure: 1.6MPa, 2.5MPa, 4.0MPa
T
Nominal diameter: 25mm
Measure range(C-C): 300, 440mm
Visible length: 165, 195(mm)
Medium temperature: <250 C degree
Visual angle: 20°; Visible distance: < 60m
Material: Q235-A quality carbon steel
Lamp: lamp inside, power AC 36V+/-4V, 6W
Medium: water, steam, oil etc.
1) Measure range: 330~440mm; 2000mm
2) Working temperature: saturation temperature
3) Working pressure: ≤4MPa
4) Meter material: qualitative
Carbon steel or 1Cr18Ni9Ti
5) Transmit color: Red for Air, Green for Water
6) Glass Material: borosilicate or Mica
1) Measure ranges: 300~2000mm
2) Work temperature: -40~60ºC
3) Working pressure: ≤4MPa
4) Needle switch close automatically pressure: ≥0.2MPa
Temp. ºC | Main material | Frost fin height H(mm) |
Color | |
No. | Name | |||
-20~0 | 20 | 50 | Gray | |
-40~21 | 16MU | 100 | purple | |
-70~41 | 09MU2V | 150 | Deep blue | |
-160~71 | 1Cr8Ni9Ti | 200 | Light blue |
1) Visible: 18×304mm
2) Working pressure: ≤1.0Mpa
3) Working temperature: ≤250ºC
4) Welded size: 80×304mm or on order.
Nominal length: 80 X 366(mm)
5) Material: Q235-A Carbon Steel, SS304.
1) Visible: 18×304mm
2) Working pressure: ≤1.0Mpa
3) Working temperature: ≤250ºC
4) Welded size: 80×304mm or on order.
Nominal length: 80 X 366(mm)
5) Material: Q235-A Carbon Steel, SS304.
TBS-G Top-bottom connection transparent level gauge
1) Range: 300-6000mm
2) Working pressure: ≤16Mpa
3) Working temperature: ≤500ºC
4) Connection: Threaded or flange
5) Mounting: Top-bottom
6) Material: Q235-A Carbon Steel, SS304.
Glass Tubular Level Gauge
This B43H-64 Tube type Water Gauge are composed by top valve (steam valve) bottom valve (water valve), gage body, Drain valve, balance pipe etc.
Top valve and bottom valve is a quickly composed valve, not only manually open quickly and all closing, as there are insurance valve and a insurance bead in valve inside, when the quartz tube suddenly blow up, insurance steel bead will quickly apical under the high pressure pop, then close the up and down passageway automatically, until Manual closing fast valve, Insurance bead will get pressure balance by balance pipe, has obtained by insurance bead self-respect, so will not appear False water and other no good phenomena.
1. Operating pressure: 1.6-10MPa
3. Length: 440-670mm
4. medium temperature:≤450 ºC
5. Material: Q235-A carbon steel
Bicolour water gauge consists of upper valve, lower valve, and gauge body, blow off valve, balancing tube and lamp house. The upper valve and lower valve can be fully opened and closed by Hand. Inside the valve body. There is a safety steel ball and safety valve seat. When the quartz glass rube is broken suddenly, the steel ball will remove to the safety valve seat in high speed pushed by high pressure steam to shut off the channel of the gauge automatically until the upper and lower valves is closed by hand. The ball will be reset by the pres-sure from the balancing tube and by its gravity. Therefore, false water level can be avoided. The gauge is provided with special safeguard, so it is safe and reliable, the gauge body itself is also a very good protection shade.
SF303, 304, 1030A water indicator: Red for Air, Green for liquid
Model | PN | Temp. | C-C | visible |
MPa | ºC | mm | mm | |
F1030A | ≤6.4 | 450 | 440 | 200 |
F1030 | ||||
F303 | 600 | 300 | ||
SF303 | ||||
F304 | ≤10.0 | 450 | 440 | 200 |
SF304 | 600 | 300 | ||
F401 | ≤4.0 | 260 | 350 | 140 |
SF401 | 440 | 200 | ||
F402 | ≤2.5 | 260 | 350 | 140 |
SF402 | 440 | 200 |
1) Measure ranges: 300~6000mm
2) Working temperature: ≤100ºC
3) Nominal pressure: PN0~10Bar
4) Meter material: carbon steel or SS304, SS316
5) flange standard: DIN,ANSI,JIS
1)flange to flange: 300~2200mm
2) Working temperature: ≤200ºC
3) Nominal pressure: PN0~6.3MPa
4) Meter material: high quality carbon steel or 1Cr18Ni9Ti
5) Flange standard and specifications: supplied by customer
6) Electric Heating: thermal belt
7) Electric Heating power: 220VAC or 24VAC
8) Electric Heating temperature: 50ºC~150ºC
1) Flange center to center: 300~1000mm
2) Working temperature: ≤450ºC
3) Nominal pressure: ≤10MPa
4) Meter material: high quality carbon steel or 1Cr18Ni9Ti
1) Measure ranges: 300~2000mm
2) Working temperature: -20~600ºC
3) Nominal pressure: PN0~10MPa
4) Meter material: Carbon steel, SS304
5) Steam Jacket connecting tube: flange DN15 or flange 1/2×1.5
If the meter without light equipment, it can be installed at the light bright place.
The flange and the sealing face can't be damaged for contaminated.
If the measure range is very wide and must use serious meter to measure, their installing place should be separated without blind zone.
When use the level gauge, water pressure should be check firstly, and the pressure the meter can bear is no more than 1.5 times of the maximum pressure. The test must conform to the pressure vessel safely requirement of the relative department.
When install series TBS meter, the top and bottom needle valves must be closed. When operating, firstly open the top needle valve to its maximum degree and then open the bottom needle valve slowly to lead the fluid into the meter. And then loose the vent valve to vent gas. After vent out the gas then tight the vent valve immediately. When turning the needle valves.
Model No. and specifications;
Measuring ranges;
Working pressure and temperature
Material
Whether have special requirements;
Whether need to supply the accessories such as flange, nut, bolt, valves and packing washer
Regulation for operation and maintenance
According to the clearness of the fluid to clean the needle valve regularly to ensure the liquid free-flow. The inner side of the glass plate can also be unload to clean when be contaminated. But the test must do every time when take off the plate and washing.
When vent air and drain the soiling should be careful to operate to prevent fluid overflow.
When glass is broken by accident, please close the needle valves or tube valve immediately.
When water level meter is used, should be preheated 20-30 minutes, when the glass plate with a certain temperature, when open on both ends of the valve, the infuse water or other medium.
During the use process, please often discharge the drainage, avoid fouling corrosion blocking channels, appear false water level phenomenon.
When replace glass, the metal filings and debris should be removed from the sealing surface.
Flat water level gauge (also called a level surface indicator), it is suitable for industrial steam boilers and steam locomotive boiler and water storage set on liquid level indicating.
Prism (or glass) must be under the equal compression when tighten thread. Tight each screw on turn several circles until to tighten torque 20-39.4 Nm.
Glass Level Gauge
Flat /Armored Glass Level Indicator
Sight glass tubular level gauge
Catalogue
Flowmeterlevel indicatorpressure transmitterSight Glass
Pressure reducing & sustaining valve, gate valve, check valve,
Ball valve, steam traps, strainers
Related products: Level Meter / boiler level gauge / liquid level transmitter / stainless steel valves
Serious Glass Sheet Level Gauge is a kind of sight glass level gauge which can show the liquid level directly. These type level gauges are widely used in chemical industries and petroleum field.
Glass type: borosilicate glass/mico/quartz
Gasket material: graphite gasket
Pressure for steel ball shut off automatically: ≥0.2Mpa
Steam pressure: ≤0.6Mpa. Steam sheath joint: G1/2″male thread
Measure range: 300~3000mm
Working temperature:-20~450ºC
Working pressure: 0.6MPa, 2.5Mpa, 4.0MPa, 6.3MPa, 16MPa
Meter material: carbon steel, SS304 or SS316.
Transmit color: nature color, or bi-color type(green for liquid, red for air)
Ordinary globe valve or 1/4 opens or close valve.
Lamp lighting: fluorescent lamp power supply AC36V
Glass sizes: 140mm, 165mm, 190mm, 218mm, 260mm, 280mm, 290mm, 320mm, 340mm;
Connection center to center distance 10mm adjustable.
When open the packing, firstly check the substance, and tight the bolt again. And then according to the picture equip with the accessories.
1) C-C distance: 350~2600mm
2) Working temperature: ≤250ºC
3) Working pressure: ≤16MPa
4) Meter material: carbon steel or 1Cr18Ni9Ti
5) Transmit color: nature color
1) Measure ranges: 300~2000mm
2) Work temperature: 0~250ºC
3) Working pressure: ≤16MPa
4) Needle switch close automatically pressure: ≥0.2MPa
5) steam insulating sheath pressure: ≤0.6MPa
6) flange material: qualitative carbon steel or 1Cr18Ni9Ti
Color: natural color
Name: flat sight glass level indicator
Nominal pressure: 2.5~4.0MPa
Nominal diameter: 25mm
Nominal length: 350mm, 440mm
Medium temperature: <250 C degree
Material: Q235-A quality carbon steel
Color: natural color
Name: flat sight glass level indicator
Nominal pressure: 1.6~4.0MPa
Nominal diameter: 25mm
Nominal length: 300~440mm
Medium temperature: <250 C degree
Material: Q235-A quality carbon steel or SS304
Color: bi-color ( red for air, green for liquid)
Nominal pressure: 1.6MPa, 2.5MPa, 4.0MPa
T
Nominal diameter: 25mm
Measure range(C-C): 300, 440mm
Visible length: 165, 195(mm)
Medium temperature: <250 C degree
Visual angle: 20°; Visible distance: < 60m
Material: Q235-A quality carbon steel
Lamp: lamp inside, power AC 36V+/-4V, 6W
Medium: water, steam, oil etc.
TBS-B Bi-color non-blind level gauges
1) Measure range: 330~440mm; 2000mm
2) Working temperature: saturation temperature
3) Working pressure: ≤4MPa
4) Meter material: qualitative
Carbon steel or 1Cr18Ni9Ti
5) Transmit color: Red for Air, Green for Water
6) Glass Material: borosilicate or Mica
1) Measure ranges: 300~2000mm
2) Work temperature: -40~60ºC
3) Working pressure: ≤4MPa
4) Needle switch close automatically pressure: ≥0.2MPa
Temp. ºC | Main material | Frost fin height H(mm) |
Color | |
No. | Name | |||
-20~0 | 20 | 50 | Gray | |
-40~21 | 16MU | 100 | purple | |
-70~41 | 09MU2V | 150 | Deep blue | |
-160~71 | 1Cr8Ni9Ti | 200 | Light blue |
1) Visible: 18×304mm
2) Working pressure: ≤1.0Mpa
3) Working temperature: ≤250ºC
4) Welded size: 80×304mm or on order.
Nominal length: 80 X 366(mm)
5) Material: Q235-A Carbon Steel, SS304.
1) Visible: 18×304mm
2) Working pressure: ≤1.0Mpa
3) Working temperature: ≤250ºC
4) Welded size: 80×304mm or on order.
Nominal length: 80 X 366(mm)
5) Material: Q235-A Carbon Steel, SS304.
1) Range: 300-6000mm
2) Working pressure: ≤16Mpa
3) Working temperature: ≤500ºC
4) Connection: Threaded or flange
5) Mounting: Top-bottom
6) Material: Q235-A Carbon Steel, SS304.
Glass Tubular Level Gauge
This B43H-64 Tube type Water Gauge are composed by top valve (steam valve) bottom valve (water valve), gage body, Drain valve, balance pipe etc.
Top valve and bottom valve is a quickly composed valve, not only manually open quickly and all closing, as there are insurance valve and a insurance bead in valve inside, when the quartz tube suddenly blow up, insurance steel bead will quickly apical under the high pressure pop, then close the up and down passageway automatically, until Manual closing fast valve, Insurance bead will get pressure balance by balance pipe, has obtained by insurance bead self-respect, so will not appear False water and other no good phenomena.
1. Operating pressure: 1.6-10MPa
3. Length: 440-670mm
4. medium temperature:≤450 ºC
5. Material: Q235-A carbon steel
Bicolour water gauge consists of upper valve, lower valve, and gauge body, blow off valve, balancing tube and lamp house. The upper valve and lower valve can be fully opened and closed by Hand. Inside the valve body. There is a safety steel ball and safety valve seat. When the quartz glass rube is broken suddenly, the steel ball will remove to the safety valve seat in high speed pushed by high pressure steam to shut off the channel of the gauge automatically until the upper and lower valves is closed by hand. The ball will be reset by the pres-sure from the balancing tube and by its gravity. Therefore, false water level can be avoided. The gauge is provided with special safeguard, so it is safe and reliable, the gauge body itself is also a very good protection shade.
SF303, 304, 1030A water indicator: Red for Air, Green for liquid
Model | PN | Temp. | C-C | visible |
MPa | ºC | mm | mm | |
F1030A | ≤6.4 | 450 | 440 | 200 |
F1030 | ||||
F303 | 600 | 300 | ||
SF303 | ||||
F304 | ≤10.0 | 450 | 440 | 200 |
SF304 | 600 | 300 | ||
F401 | ≤4.0 | 260 | 350 | 140 |
SF401 | 440 | 200 | ||
F402 | ≤2.5 | 260 | 350 | 140 |
SF402 | 440 | 200 |
1) Measure ranges: 300~6000mm
2) Working temperature: ≤100ºC
3) Nominal pressure: PN0~10Bar
4) Meter material: carbon steel or SS304, SS316
5) flange standard: DIN,ANSI,JIS
1)flange to flange: 300~2200mm
2) Working temperature: ≤200ºC
3) Nominal pressure: PN0~6.3MPa
4) Meter material: high quality carbon steel or 1Cr18Ni9Ti
5) Flange standard and specifications: supplied by customer
6) Electric Heating: thermal belt
7) Electric Heating power: 220VAC or 24VAC
8) Electric Heating temperature: 50ºC~150ºC
1) Flange center to center: 300~1000mm
2) Working temperature: ≤450ºC
3) Nominal pressure: ≤10MPa
4) Meter material: high quality carbon steel or 1Cr18Ni9Ti
1) Measure ranges: 300~2000mm
2) Working temperature: -20~600ºC
3) Nominal pressure: PN0~10MPa
4) Meter material: Carbon steel, SS304
5) Steam Jacket connecting tube: flange DN15 or flange 1/2×1.5
If the meter without light equipment, it can be installed at the light bright place.
The flange and the sealing face can't be damaged for contaminated.
If the measure range is very wide and must use serious meter to measure, their installing place should be separated without blind zone.
When use the level gauge, water pressure should be check firstly, and the pressure the meter can bear is no more than 1.5 times of the maximum pressure. The test must conform to the pressure vessel safely requirement of the relative department.
When install series TBS meter, the top and bottom needle valves must be closed. When operating, firstly open the top needle valve to its maximum degree and then open the bottom needle valve slowly to lead the fluid into the meter. And then loose the vent valve to vent gas. After vent out the gas then tight the vent valve immediately. When turning the needle valves.
Model No. and specifications;
Measuring ranges;
Working pressure and temperature
Material
Whether have special requirements;
Whether need to supply the accessories such as flange, nut, bolt, valves and packing washer
Regulation for operation and maintenance
According to the clearness of the fluid to clean the needle valve regularly to ensure the liquid free-flow. The inner side of the glass plate can also be unload to clean when be contaminated. But the test must do every time when take off the plate and washing.
When vent air and drain the soiling should be careful to operate to prevent fluid overflow.
When glass is broken by accident, please close the needle valves or tube valve immediately.
When water level meter is used, should be preheated 20-30 minutes, when the glass plate with a certain temperature, when open on both ends of the valve, the infuse water or other medium.
During the use process, please often discharge the drainage, avoid fouling corrosion blocking channels, appear false water level phenomenon.
When replace glass, the metal filings and debris should be removed from the sealing surface.
Flat water level gauge (also called a level surface indicator), it is suitable for industrial steam boilers and steam locomotive boiler and water storage set on liquid level indicating.
Prism (or glass) must be under the equal compression when tighten thread. Tight each screw on turn several circles until to tighten torque 20-39.4 Nm.