Manufactured Specifically for Each Application
Every Magnetic Level Indicator is designed and manufactured specifically for each Level Application. Careful attention is given to process conditions, most importantly the Specific Gravity, Temperature and Pressure of the liquid to be measured.
Extreme caution should be taken before applying a Magnetic Level Indicator to a differing application, or should the original process conditions differ from those for which the Magnetic Level Indicator has been designed. Please consult the factory to make sure that the instrument can withstand and/or operate under these modified requirements.
Shipment
Special care is taken to ensure that every Magnetic Level Indicator arrives complete with all parts required and ready for float installation and commissioning. Carefully inspect every package to ensure that it has not been damaged during shipping. If damage is observed, immediately contact the shipping company that delivered the instrument and file a claim.
Unpacking/Inspection
Upon opening of the shipping container, carefully inspect each instrument to ensure that it has arrived in good order and without damage. Note that the process conditions are listed on the tag mounted at the base of the indicator assembly. Make sure that these process conditions match the application for which this gauge is designed.
Should there be damage to The Series Magnetic Level Indicator, try to take digital pictures if possible. Take note of the serial number of the instrument and consult the factory so that we can take action to repair/replace this instrument.
Storage
Although these level instruments are manufactured for installations that are not necessarily sheltered from the environment, care should be taken to ensure that no damage occurs from the time these instruments are delivered to the time that they are installed or while in storage. Packaging is designed to withstand shipping and lifting. It will not withstand continual moisture from rain or rising water. Instruments should be stored in a dry place under shelter, if possible, in temperatures not below 32 or above 150 Degrees Fahrenheit. Objects should not be stacked on top of these packaged instruments.
How The Series Magnetic Level Indicator Works
Each Series Magnetic Level consists of three basic parts.
- The Chamber: Usually manufactured out of Stainless Steel, but available in Hastelloy, Alloy 20, and other materials. The chamber allows for measurement as well as containment of the liquid to be measured.
- The Float: Contains a Magnet assembly. The float is engineered to ensure buoyancy based on the specific gravity, temperature, and pressure of the liquid to be measured. Each float is weighted so the liquid level will be equal to the position at which the magnet is mounted in the float.
- The Indicator: Mounted outside of the chamber, includes magnetized wafers or flags that react to the magnet included in the float.
The chamber is mounted parallel to the tank application. The liquid level in the chamber will match the movement of the liquid level of the tank. The float movement matches the liquid movement and causes the reaction of the visual indicator.
How to Install The Series Magnetic Level Indicator
Use care in lifting the instrument from the package or crate. Remove any flange covers or thread caps. If possible, always install isolation valves between the Level Gauge and the process tank. This will allow for gradual pressurization of the Level Gauge chamber as well as facilitate any future maintenance necessary. The gauge should be mounted level to ensure proper float travel without friction.
WARNING:
IF THIS CHAMBER OR SYSTEM REQUIRES A HYDROSTATIC TEST, THE FLOAT MUST NOT BE INSTALLED WITH TESTING!
The float is designed to withstand the maximum pressure specified for the level application. Damage can occur to the float if it is not removed during Hydrostatic Testing.
Once the hydrostatic test is complete, the float should be installed in the Magnetic Level Indicator chamber. Each float is etched with the serial number of the instrument, the specific gravity, and arrows “Up” showing the correct positioning of the float in the chamber. The end of the float with the “Up” arrows should be positioned upward as the float is deployed in the instrument. If the float is installed upside down, problems will arise with associated instruments and the accuracy of the level gauge.
IMPORTANT!
Once the Magnetic Level Indicator is attached to the application and the vent and drain connections are confirmed to be closed, utilize the following procedure for start up, ESPECIALLY FOR HIGH PRESSURE AND TEMPERATURE APPLICATIONS!
- Slowly open the top Valve first. This will allow for equalization of pressure in the chamber to the process.
- Slowly open the bottom Valve. Liquid can now fill the chamber gradually.
Failure to follow this procedure can lead to damage of the float!
The tank level should be raised to maximum height to check the upper connection for leaks. If applicable, verify that all switch operation is correct and that the transmitter indicates the correct level.
WARNING
Once the pressure in the Gauge Chamber has been equalized with the process pressure, DO NOT open the vent or drain connections. Damage to the float can occur!
See the section entitled “Maintenance” to learn the proper procedure for removing this instrument from service.
Functional Test
The best way to provide a functional test for this instrument is to raise and lower the level of the material in the tank, and, therefore, the gauge. Many times this is not possible. If this is the case, utilize one of the following options.
- Make sure the chamber is isolated from process conditions by closing the valves at the connection points. Drain off any remaining liquid in a manner compatible with plant requirements. As most floats will be buoyant upon water, slowly fill the level gauge through the vent connection. Observe the movement of the visual indicator as the gauge fills with water. If applicable, monitor the outputs of switches and transmitters accompanying this instrument.
- If it is not possible to fill the gauge with water or another liquid, either open the drain connection or remove the bottom flange. Carefully manipulate the float with a piece of instrument tubing or a device that affects the movement of the float in the chamber. Observe the movement of the visual indicator as the float moves. If applicable, monitor the outputs of switches and transmitters accompanying this instrument.
- Often times there will not be enough ground clearance to insert an object to manipulate the float. If this is the case, such a test can be completed prior to installation while the instrument is lying on a workshop bench.
Maintenance
Normally, Magnetic Level Indicators operate free from maintenance and wear when applied properly. Depending on the application, occasionally mud or other floating substances can gather in the lower portion of the instrument. Should this be the case, follow the below steps to remove the gauge from service.
- Isolate the chamber from service by closing the process valves starting with the lower valve and then the top valve.
- Allow pressure to equalize with atmosphere by slowly opening the vent connection.
- Drain off any remaining liquid in a manner compatible with plant requirements.
- Remove the flange on the bottom of the gauge.
Caution!
Take care to not allow the float to drop on the floor.
This can cause damage to the float and/or the magnet assembly.
- Clean out chamber with a brush and wash with water if compatible. Make sure there are no remaining solid particles. Look for items or debris that will inhibit the movement of the float. Further inspect the gauge chamber to ensure that it is free from unexpected corrosion or damage.
- Replace the float with the arrows in the “Up” position.
- Using a new gasket, replace the bottom flange and tighten all fasteners to the proper torque.