Ywz-80t-100t Liquid Level Gauge Mechanical Oil Level Indicator with Temperature Indicator

Quick Details
Model NO.:YWZ
Certification:CE, UL, RoHS
Material:SS304
Process Temperature:-40~120℃
Medium:Oil, Liquid,
Working Temperature:<= 200 Dgree C
Working Pressure:0.1 ~ 0.15MPa
Case Cover:Cast Aluminium or Plastic
Warranty Period:1year
Center to Center:76mm to 500mm
Trademark:U-ideal
Transport Package:Wooden Cases or Carton
Specification:sgs, iso
Product Introduction
The Ywz-80t-100t Liquid Level Gauge Mechanical Oil Level Indicator with Temperature Indicator which supplied from our company are essential accessories of oil tank, oil cellar, cooling case and gear box. This YWZ-T type oil gauge can indicate both liquid level and liquid temperature.
These type of oil level gauges are an attractive, new and unique type, and can indicate liquid level and temperature clearly. Good assembly performances; fixed installation, crack control, shockproof and leakage proof and their advantages. These type of oil level gauges are designed to 25 different kinds' specifications according the oil tank volume. We assure the products quality for one year, and welcome all new and old customer to try these type products.
Model Explanation

Example:
YWZ-80: Oil gauge without thermometer for hydraulic oil.
YWZBH-80T: Oil gauge with thermometer for water-ethylene glycol.
Model Selection oil YWZ-T oil Level gauge
| MODEL | Size(mm) center to center distance | ||
| L (Gauge) | E (C-C) | B (Indicator) | |
| YWZ-76 | 106 | 76 | 37 |
| YWZ-76T | |||
| YWZ-80 | 110 | 80 | 42 |
| YWZ-80T | |||
| YWZ-100 | 130 | 100 | 62 |
| YWZ-100T | |||
| YWZ-125 | 155 | 125 | 87 |
| YWZ-125T | |||
| YWZ-127 | 157 | 127 | 89 |
| YWZ-127T | |||
| YWZ-150 | 180 | 150 | 112 |
| YWZ-150T | |||
| YWZ-160 | 190 | 160 | 122 |
| YWZ-160T | |||
| YWZ-200 | 230 | 200 | 162 |
| YWZ-200T | |||
| YWZ-250 | 280 | 250 | 212 |
| YWZ-250T | |||
| YWZ-254 | 284 | 254 | 215 |
| YWZ-254T | |||
| YWZ-300T | 330 | 300 | 262 |
| YWZ-350T | 380 | 350 | 312 |
| YWZ-400T | 430 | 400 | 362 |
| YWZ-450T | 480 | 450 | 412 |
| YWZ-500T | 530 | 500 | 462 |


YWZ Series Oil‑Temperature & Level Gauge
Short catalog version
YWZ Oil‑Level Gauge – Installation Notes
- Mount vertically on the side wall of oil tank, keep the scale upright for correct reading.
- Avoid impact, bending and heavy load on the gauge body during installation.
- Tighten fittings evenly; do not over‑torque to prevent cracking of the glass or plastic tube.
- Select compatible gaskets resistant to hydraulic oil to avoid leakage.
- Keep away from heat sources and direct flame.
Common Faults & Solutions
-
Oil leakageUneven tightening or damaged gasket. Replace gasket and fasten screws evenly.
-
Blurred viewing surfaceOil contamination or dirt. Clean the surface; check oil quality inside the tank.
-
Incorrect level readingInclined installation or blocked inner channel. Re‑install vertically, clear blockages.
-
Temperature indicator fails (for temperature‑integrated type)Thermo‑element damaged. Replace the complete YWZ gauge assembly.