J\K\E\T\PT100\CU50 All types Thermocouple Thermal resistance

Application:
Thermocouple Thermal resistance are widely used in science and industry; applications include temperature measurement for kilns, gas turbine exhaust, diesel engines, and other industrial processes. Thermocouples are also used in homes, offices and businesses as the temperature sensors in thermostats, and also as flame sensors in safety devices for gas-powered major appliances.

J\K\E\T\PT100\CU50 All types Thermocouple Thermal resistance are manufactured in many different configurations for multitude of applications.Diameters,lengths,sheath material,lead material,lead lengths and sensor material are just a few of the variable that go into determining the style of thermocouple when manufactured.The main determining factors of what type thermocouple needs to be used in a application is temperature, environment response time and accuracy.The junction of the thermocuple can be grounded,ungrounded or exposed.The lead length may vary depending on the distance of the temperature controller from the thermocouple sensor.The metal that the sensor is constructed by determines the type of thermocouple manufactured.
Thermocouple Thermal resistance are widely used in science and industry; applications include temperature measurement for kilns, gas turbine exhaust, diesel engines, and other industrial processes. Thermocouples are also used in homes, offices and businesses as the temperature sensors in thermostats, and also as flame sensors in safety devices for gas-powered major appliances.
Thermocouple Thermal resistance Product Paramenters:
| Input | |
| Input signal | Thermal Resistance (RTD), thermal couple (TC), linearity resistance |
| Cold end compensation temperature range | -20~60℃ |
| Compensation accuracy | ±1℃ |
| Output | |
| Output Signal | 4-20mA |
| Load resistance | RL≤ (Ue-12)/0.021 |
| Upper and lower limit overflow alarm output current. | IH=21mA、IL=3.8mA |
| Power off alarm signal | 21mA |
| Power voltage | DC12-40V |
| Other Parameter | |
| Transmitting accuracy(20℃) | 0.1%FS |
| Temperature drift | 0.01%FS/℃ |
| Response time | 1s reach 90% of final value |
| The environment temperature | -40~80℃ |
| Storage temperature | -40~100℃ |
| Condensate | Allow |
| Protection class | IP00;IP66(install) |
| Shock proof | 4g/2~150Hz |
| Mount Angle | Any |
| Mounting area | B type top box mounting |
| Magnetic compatibility | Conform to GB/T18268 industrial device requirements(IEC 61326-1) |
| Model | Type | Measure range | Min measure range |
| Thermal resistance (RTD) | Pt100 | -200~850℃ | 10℃ |
| Cu50 | -50~150℃ | 10℃ | |
| Thermal Couple (TC) | B | 400~1820℃ | 500℃ |
| E | -100~1000℃ | 50℃ | |
| J | -100~1200℃ | 50℃ | |
| K | -180~1372℃ | 50℃ | |
| N | -180~1300℃ | 50℃ | |
| R | -50~1760℃ | 500℃ | |
| S | -50~1760℃ | 500℃ | |
| T | -200~400℃ | 50℃ | |
| Wre3-25 | 0~2315℃ | 500℃ | |
| Wre5-26 | 0~2310℃ | 500℃ |
View other Thermocouple Thermal resistance related products, visit the Chinese website for Thermocouple Thermal resistance